Here are the programming instructions for a 1996 Cadillac Seville Key Fob Remote. If you need an extra Key Fob or Replacement Fob for any vehicle you might have visit us at Keylessentryremotefob.com You can also leave comments or suggestions at the bottom of this blog and if you like what we provide please forward on to your friends & family; people like you are our best advertising tool!
ORDER THIS KEY FOB PART NUMBER HERE: 16259819
PLEASE NOTE: When you begin the programming sequence to sync your remote to your installed remote keyless entry (RKE) system, you MUST HAVE ALL OF YOUR REMOTES (Including PREVIOUSLY PROGRAMMED remote(s)) to be programmed with you at the time of programmingâ¦
ALL PREVIOUSLY PROGRAMMED REMOTES WILL BE ERASED AT THIS TIME.
(This is a safety feature which prevents anyone else from accessing your vehicle.)
UP TO 4 REMOTES (total) may be programmed to your vehicleâs system at one time.
KEYLESS REMOTE PROGRAMMING PROCEDURE:
AT TIME OF PROGRAMMING:
ALL remotes to be programmed and/or reprogrammed MUST BE PRESENT.
METHOD #1:
Use these instuctions if your Deville has an Analog Instrument Cluster
1. Press OFF and WARM buttons on Climate Control Panel (CCP) simultaneously.
(Instrument Panel Cluster (IPC) will light all telltales, then go blank) System is now in diagnostic mode. Press PASSENGER COOLER button until âRFAâ is displayed, then press FAN UP.
If âRFA DATAâ is displayed, press FAN DOWN.
If âRFA OVERRIDEâ is displayed, press FAN UP.
2. If âRFA 500 NO OVERRIDEâ is displayed, press FAN DOWN.
If âRFA 501 PROGRAM FOB #1â is displayed, Press FAN UP.
3. IPC will show â0â on right side of Driver Information Center (DIC) display. Press warmer button on climate control unit until â99â is displayed.
4. Press and hold TRUNK button on transmitter. While holding TRUNK button, press LOCK button and hold for one second. Hold both buttons for a total of 3 seconds. Locks cycle when programming is complete (if remote is not programmed within 30 seconds after entering â99â override display, system will default and you must begin again at step 2.
5. To program a second remote, press FAN DOWN button until âRFA 502 PROGRAM FOB #2â is displayed, then press FAN UP. Repeat step 4.
To exit system, press AUTO, MODE UP, MODE DOWN, or RESET.
METHOD #2:
Use these instructions if your DeVille has a Digital Instrument Cluster
1. Press OFF and WARM buttons on Climate Control Center (CCC) simultaneously. Instrument Panel Cluster (IPC) will light all telltales, go blank then enter DIAGNOSTIC MODE. Press FAN DOW button to scroll through system until âRFAâ is displayed, then press FAN UP button. Press FAN DOWN button until âRFA OVERRIDEâ is displayed, then press FAN UP button. When âNO OVRD RF 500â is displayed, then press FAN UP button.
2. When âPGM FOBL 501â is displayed, press WARM button and â99â will be displayed in left upper corner of IPC just below odometer. System is now ready to program remote.
3. Press and hold TRUNK button on transmitter. While holding TRUNK button, press LOCK button and hold for one second. Hold both buttons for a total of 3 seconds. Locks cycle when programming is complete (if remote is not programmed within 30 seconds after entering â99â override display, system will default and you must begin again at step 2.)
4. To program second remote, pres FAN UP button until âPGM FOB2 502â is displayed, then follow steps 2 and 3 to program second remote.
To exit system, press RECIRC or RESET buttons.
Subscribe To Our Social Networks For Special Discounts, Offers, & Contests!
By Keyless Entry Remote Inc